Article
Ball-in-socket medial conformity with posterior cruciate ligament retention neither limits internal tibial rotation and knee flexion nor lowers clinical outcome scores after unrestricted kinematically aligned total knee arthroplasty
Search Medline for
Authors
Published: | October 23, 2023 |
---|
Outline
Text
Objectives: For a tibial insert with ball-in-socket medial conformity, PCL retention, and flat lateral articular surface (B-in-S MC+PCL), this study determined whether internal tibial rotation and knee flexion were limited and clinical outcome scores were lower during weight-bearing activities relative to an insert with intermediate (i.e. less than ball-in-socket) medial conformity (I MC+PCL). Figure 1 [Fig. 1]
Methods: Twenty-five patients were treated with bilateral unrestricted, caliper-verified kinematic alignment (KA) TKA with an I MC+PCL insert and B-in-S MC+PCL insert in opposite knees. Each patient performed weight-bearing deep knee bend, step-up, and chair rise under single-plane fluoroscopy. Analysis following 3D model-to-2D image registration determined internal tibial rotation. For each TKA, knee flexion was measured and patients completed clinical outcome scoring questionnaires.
Results: Internal tibial rotation did not differ between conformities during chair rise and step-up (p=0.3419 and 0.1030, respectively). During deep knee bend, internal tibial rotation between 90º and maximum flexion was 3º greater in the B-in-S MC+PCL group (18° vs 15º) (p=0.0290). Mean knee flexion (p=0.3115) and median FJS, OKS, and WOMAC scores (p=0.2100, 0.2154, and 0.4542, respectively) did not differ between conformities (Table 1 [Tab. 1])
Conclusion: An insert with ball-in-socket medial conformity, which maximizes AP stability, did not limit internal tibial rotation and knee flexion and did not lower patient-reported outcomes when implanted with unrestricted caliper-verified KA and PCL retention. These results suggest that surgeons treating patients interested in high-level and athletic activities could use ball-in-socket medial conformity and PCL retention to restore AP stability like the native knee.