gms | German Medical Science

64th Annual Meeting of the German Society of Neurosurgery (DGNC)

German Society of Neurosurgery (DGNC)

26 - 29 May 2013, Düsseldorf

Transaqueductal fenestration of the Lamina terminalis using a flexible endoscope

Meeting Abstract

  • Sonja Vulcu - Neurochirurgische Klinik, Universitätskliniken des Saarlandes, Homburg/Saar
  • Hayk Bloutian - Neurochirurgische Klinik, Universitätskliniken des Saarlandes, Homburg/Saar
  • Kurt Becker - Institut für Anatomie, Zellbiologie und Entwicklungsbiologie, Universität des Saarlandes, Homburg/Saar
  • Joachim Oertel - Neurochirurgische Klinik, Universitätskliniken des Saarlandes, Homburg/Saar

Deutsche Gesellschaft für Neurochirurgie. 64. Jahrestagung der Deutschen Gesellschaft für Neurochirurgie (DGNC). Düsseldorf, 26.-29.05.2013. Düsseldorf: German Medical Science GMS Publishing House; 2013. DocMI.16.11

doi: 10.3205/13dgnc426, urn:nbn:de:0183-13dgnc4261

Published: May 21, 2013

© 2013 Vulcu et al.
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by-nc-nd/3.0/deed.en). You are free: to Share – to copy, distribute and transmit the work, provided the original author and source are credited.


Outline

Text

Objective: Recently, the authors presented the transventricular, transforaminal fenestration of the Lamina terminalis (LT) as an alternative to standard endoscopic third ventriculostomy (ETV). Fenestration was feasible with a flexible and a rigid endoscope but with the hazard of fornical contusion due to the steep angle to LT. To avoid contusion and provide a flatter angle, the authors now investigate the feasibility of LT fenestration using a flexible endoscope via a transaqueductal approach.

Method: Ten cadaver specisms underwent LT fenestration with a small flexible endoscope (diameter 2.7 mm) through a suboccipital approach. After passing the fourth ventricle and the aqueduct, LT was fenestrated with the aid of grasping forceps and fogarty balloon catheter.

Results: Passage of the aqueduct and fenestration of LT succeeded in all cadavers with the flexible endoscope. No damage of the aqueduct or anatomical structures in the third ventricle occurred. Identification of anatomical landmarks in the third ventricle and even in the lateral ventricles after passing foramen of Monro was good possible.

Conclusions: The transaqueductal fenestration of LT with the flexible endoscope might present an alternative in cases where standard ETV is not feasible. However, handling of the instruments for fenestration is more difficult in a flexible system; additionally, the optical image quality is much worse, therefore, this procedure should be reserved for experienced hands. To gain more experience and to draw definite conclusions, clinical application in a patient series is necessary in future.