gms | German Medical Science

GMS Ophthalmology Cases – An Open Access Journal

Bundesverband Deutscher OphthalmoChirurgen e. V. (BDOC)

ISSN 2193-1496

Trocar-assisted, flanged sutureless scleral-fixated intraocular lens implantation combined with silicone oil injection after penetrating keratoplasty surgery

Case Report

  • corresponding author Remzi Karadag - Department of Ophthalmology, Istanbul Medeniyet University School of Medicine, Goztepe, Istanbul, Turkey
  • Guler Kilic - Department of Ophthalmology, Istanbul Medeniyet University Goztepe Research and Training Hospital, Goztepe, Istanbul, Turkey
  • Aylin Ardagil - Department of Ophthalmology, Istanbul Medeniyet University Goztepe Research and Training Hospital, Goztepe, Istanbul, Turkey
  • Ahmet Demirok - Department of Ophthalmology, Istanbul Medeniyet University School of Medicine, Goztepe, Istanbul, Turkey

GMS Ophthalmol Cases 2020;10:Doc03

doi: 10.3205/oc000130, urn:nbn:de:0183-oc0001301

Published: February 14, 2020

© 2020 Karadag et al.
This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 License. See license information at http://creativecommons.org/licenses/by/4.0/.


Abstract

We describe a combined technique of trocar-assisted sutureless scleral-fixated intraocular lens implantation and silicone oil injection at the same session. Two 3 mm scleral tunnels were created 2 mm away from and parallel to the limbus with the 23-gauge vitrectomy trocars entering the sclera transconjunctivally at an angle of approximately 10° at the 3 o’clock and 9 o’clock meridians. After the 3-piece foldable IOL was delivered to the anterior chamber through the corneal incision, the tip of one of the IOL haptics was grasped with a 23-gauge serrated retinal forceps entered through the trocar located at the 3 o’clock meridian. Then the haptic was removed from the scleral tunnel together with the trocar out of the globe. The same procedure was applied to the other haptic. A transconjunctival secure 10-0 nylon suture was placed at the scleral tunnel entry site around the haptic. The ends of the haptics were cauterized to make a flange. The resultant flanges of the haptics were pushed back and fixed into the scleral tunnels. Perfluorooctane was taken out of the eye with vitreoretinal surgery and the silicone was injected into the eye to prevent hypotonia. No complications were seen intraoperatively or postoperatively. After 1-month follow-up period, IOL was seen stabilized.

Keywords: intraocular lens, silicone oil, sutureless, sutureless intrascleral fixation, trocar, sutureless sclera fixation


Introduction

In patients with inadequate capsular support, there are many methods for intraocular lens (IOL) implantation. These include anterior chamber IOL implantation, iris-fixated IOL, and scleral-fixated IOL implantation techniques [1]. Each of these methods has its specific advantages and disadvantages [1]. Sutureless scleral fixation (SSF) IOL implantation methods have recently become popular due to suture-related complications such as inflammation, infection, and suture break or degradation, which results in IOL dislocation [1], [2], [3]. Many different techniques have been described for sutureless scleral IOL fixation [3], [4], [5]. After obtaining successful results with SSF techniques, now these techniques have begun to be applied in a combined surgery [6], [7], [8]. Yet, there are few publications in the literature about this technique combined with other surgeries, these being only case reports [6], [7], [8].

In this article, we aimed to present the operation of SSF IOL implantation and silicone oil injection at the same session due to postoperative hypotonia and aphakia in a patient who had previously undergone keratoplasty because of corneal opacification due to toxic anterior segment syndrome (TASS).


Case description

A 51-year-old male patient who underwent cataract surgery previously in another center developed retinal detachment in the same eye approximately 24 months after the cataract surgery and retinal detachment surgery was performed in our clinic. After this surgery, TASS developed in the patient and corneal opacification and intense membranes occurred around the iris, ciliary body, and intraocular lens despite extensive treatment. This was followed by penetrating keratoplasty. The cyclitic membranes were cleaned and IOL extraction was performed. Postoperatively, the corneal graft was transparent and the visual acuity level of the patient was hand motion. Since our patient had hypotonia for 4 months following surgery as a result of ciliary body shut down, we planned the implantation of trocar-assisted SSF IOL and silicone oil injection at the same session. Surgery was performed as briefly described below: Three 23-gauge vitreoretinal trocars were placed in the pars plana at 2, 8 and 10 o’clock (Figure 1a [Fig. 1]). Then perfluorooactane was given (Figure 1b [Fig. 1]) and appropriate intraocular pressure (IOP) was obtained. Two 3 mm scleral tunnels were created 2 mm away from and parallel to the limbus with the 23-gauge vitrectomy trocars entering the sclera transconjunctivally at an angle of approximately 10° at the 3 o’clock and 9 o’clock meridians and entered into the posterior chamber (Figure 1c–e [Fig. 1]). After the 3-piece foldable IOL was delivered to the anterior chamber through the corneal incision (Figure 1f [Fig. 1]), the tip of one of the IOL haptics was grasped with a 23-gauge serrated retinal forceps entered through the trocar located at the 3 o’clock meridian (Figure 2a [Fig. 2]). And then the haptic was removed from the scleral tunnel together with the trocar out of the globe (Figure 2b [Fig. 2]). After these procedures, a transconjunctival safety 10-0 nylon suture was placed at the scleral tunnel entry site (Figure 2c [Fig. 2]). The same procedure was applied to the other haptic (Figure 2d,e [Fig. 2]). The ends of the haptics were cauterized to make a flange (Figure 2f [Fig. 2]). The resultant flanges of the haptics were pushed back and fixed into the scleral tunnels. After completion of these procedures, perfluorooctane-air, air-silicone exchange was performed (Figure 3a,b [Fig. 3]) to prevent hypotonia. The trocars placed were removed and 3 trocar entries were sutured with 7/0 vycril suture and the operation was terminated (Figure 3c [Fig. 3]). The safety 10-0 nylon sutures were removed 1 week later. It was observed that intraocular pressure was elevated and the visual acuity level of the patient was counting fingers at 1 meter at the first postoperative month.


Discussion

In case of insufficient capsular support, scleral-fixated intraocular lenses are the method frequently used in patients [1]. One of the most serious sight-threatening complications of IOL implantation with scleral fixation is endophthalmitis and this complication is associated with suture [2]. In the literature, as suture-related complications increase, SSF methods became common [3], [4], [5]. As experience was gained with SSF IOL implantation, the cases in which this method was combined with other surgeries have begun to be published. As the first combined surgery, Prakash and colleagues reported an SSF method using fibrin glue with a femtosecond laser-assisted DSEAK (Descemet’s stripping automated endothelial keratoplasty) surgery in 3 cases [6]. In our previous study, we described the intraocular lens implantation with trocar-assisted SSF combined with penetrating keratoplasty in 4 patients [7]. Afterwards, Sethi and colleagues published a combined surgery of implantation of SSF IOL using a 26-gauge needle in combination with penetrating keratoplasty in 10 cases [8]. In addition to these combined surgeries, we successfully performed SSF surgery with removal of silicone oil from two eyes who underwent vitreoretinal surgery and we observed no complication [9]. In the case presented, we performed surgery of silicone oil injection and trocar-assisted SSF IOL implantation in a case developing hypotonia following surgery of penetrating keratoplasty and cyclitic membrane cleaning performed in the patient with corneal opacification due to TASS occurring after vitreoretinal surgery. To the best of our knowledge, this is the first case in the literature who has undergone surgery in this way. Our patient had undergone penetrating keratoplasty and IOL extraction surgery 2 months ago and he had inadequate capsular support. In patients with insufficient capsule support and who underwent penetrating keratoplasty, the most appropriate method of secondary IOL implantation is still controversial [1], [2], [10]. Scleral fixated IOL lens implantation is more frequently preferred to iris-fixated implantation because of complications such as long learning process, pigment dispersion syndrome, and IOL dislocation [10]. Recently, SSF IOL implantation has begun to be used more often because it does not cause suture-related complications. Since a scleral flap is not created, also the duration of surgery is getting shorter. However, in addition to other complications, this technique has unique complications such as early spontaneous IOL dislocation, persistent hypotony, subconjunctival haptic, and conjunctival erosion due to haptic exposure. Moreover, it needs a learning curve and special tools [3].

In conclusion, trocar-assisted SSF method is a suitable surgical method for combination with posterior segment approaches since it is distant from graft endothelium in cases previously having undergone penetrating keratoplasty and because it has few intraocular manipulations and prevents suture-related complications.


Notes

Competing interests

The authors declare that they have no competing interests.


References

1.
Wagoner MD, Cox TA, Ariyasu RG, Jacobs DS, Karp CL; American Academy of Ophthalmology. Intraocular lens implantation in the absence of capsular support: a report by the American Academy of Ophthalmology. Ophthalmology. 2003 Apr;110(4):840-59. DOI: 10.1016/s0161-6420(02)02000-6 External link
2.
Schechter RJ. Suture-wick endophthalmitis with sutured posterior chamber intraocular lenses. J Cataract Refract Surg. 1990 Nov;16(6):755-6. DOI: 10.1016/s0886-3350(13)81021-8 External link
3.
Karadag R, Celik HU, Bayramlar H, Rapuano CJ. Sutureless Intrascleral Fixated Intraocular Lens Implantation. J Refract Surg. 2016 Aug;32(9):586-97. DOI: 10.3928/1081597X-20160601-03 External link
4.
Totan Y, Karadag R. Trocar-assisted sutureless intrascleral posterior chamber foldable intra-ocular lens fixation. Eye (Lond). 2012 Jun;26(6):788-91. DOI: 10.1038/eye.2012.19 External link
5.
Totan Y, Karadag R. Two techniques for sutureless intrascleral posterior chamber IOL fixation. J Refract Surg. 2013 Feb;29(2):90-4. DOI: 10.3928/1081597X-20130117-02 External link
6.
Prakash G, Agarwal A, Jacob S, Kumar DA, Chaudhary P, Agarwal A. Femtosecond-assisted descemet stripping automated endothelial keratoplasty with fibrin glue-assisted sutureless posterior chamber lens implantation. Cornea. 2010 Nov;29(11):1315-9. DOI: 10.1097/ICO.0b013e3181cb4120 External link
7.
Karadag R, Bayramlar H, Azari AA, Rapuano CJ. Trocar-Assisted, Sutureless, Scleral-Fixated Intraocular Lens Implantation Combined With Penetrating Keratoplasty. Cornea. 2016 Sep;35(9):1261-5. DOI: 10.1097/ICO.0000000000000944 External link
8.
Sethi HS, Naik MP, Gupta VS. 26-G needle-assisted sutureless glueless intrascleral haptic fixation for secondary ciliary sulcus implantation of three-piece polymethylmethacrylate intraocular lens during penetrating keratoplasty. Taiwan J Ophthalmol. 2016 Jul-Sep;6(3):141-4. DOI: 10.1016/j.tjo.2016.04.008 External link
9.
Totan Y, Karadag R. New approach: removal of silicone oil and trocar assisted sutureless scleral fixated intraocular lens implantation at the same session. Int J Ophthalmol. 2014;7(4):734-6. DOI: 10.3980/j.issn.2222-3959.2014.04.28 External link
10.
Gonnermann J, Torun N, Klamann MK, Maier AK, Sonnleithner CV, Joussen AM, Rieck PW, Bertelmann E. Visual outcomes and complications following posterior iris-claw aphakic intraocular lens implantation combined with penetrating keratoplasty. Graefes Arch Clin Exp Ophthalmol. 2013 Apr;251(4):1151-6. DOI: 10.1007/s00417-012-2226-y External link