Traumatic wound dehiscence following penetrating keratoplasty

Meeting Abstract

Suche in Medline nach

  • D. Pahor - Department of Ophthalmology, Maribor Teaching Hospital, Maribor, Slovenia
  • B. Gračner - Department of Ophthalmology, Maribor Teaching Hospital, Maribor, Slovenia
  • T. Gračner - Department of Ophthalmology, Maribor Teaching Hospital, Maribor, Slovenia

Deutsche Ophthalmologische Gesellschaft e.V.. 104. Jahrestagung der Deutschen Ophthalmologischen Gesellschaft (DOG). Berlin, 21.-24.09.2006. Düsseldorf, Köln: German Medical Science; 2006. Doc06dogFR.14.02

Die elektronische Version dieses Artikels ist vollständig und ist verfügbar unter: http://www.egms.de/de/meetings/dog2006/06dog252.shtml

Veröffentlicht: 18. September 2006

© 2006 Pahor et al.
Dieser Artikel ist ein Open Access-Artikel und steht unter den Creative Commons Lizenzbedingungen (http://creativecommons.org/licenses/by-nc-nd/3.0/deed.de). Er darf vervielfältigt, verbreitet und öffentlich zugänglich gemacht werden, vorausgesetzt dass Autor und Quelle genannt werden.


Gliederung

Text

Objective

Blunt ocular trauma to a corneal transplanted eye represents a higher risk for wound rupture at the donor-recipient interface. We evaluate the causes, clinical characteristics, treatment and outcome, particularly the graft’s clarity in patients with traumatic wound dehiscence after penetrating keratoplasty.

Methods

Between March 1996 and April 2006, over a period of 10 years, 4 patients who had previously undergone successful penetrating keratoplasty and subsequently sustained traumatic wound dehiscence were treated at our department. All eyes underwent primary wound closure with interrupted 10-0 nylon sutures.

Results

Over the 10-year period, the incidence of traumatic wound dehiscence in which penetrating keratoplasty was performed was 2.35% (4 of 170 patients). The age of our patients at the time of injury was 6, 39, 76 and 78 years. The interval between penetrating keratoplasty and trauma varied from 12, 16, 17 to 30 months. All corneal dehiscence occurred at the graft-host junction without particular site or quadrant preference. Two eyes that were pseudophakic had lost their implants and required anterior vitrectomy. In one of these patients (a 76-year-old woman) delayed-onset expulsive choroidal hemorrhage occurred at the end of surgical repair. Visual outcome was defined with force of trauma, previous eye conditions and complication during surgery. All of the resutured grafts retained clarity.

Conclusions

Traumatic wound dehiscence is a serious and not rare complication following penetrating keratoplasty. Despite severe trauma, graft transparency was achieved in all cases and there was no need for regrafting.