gms | German Medical Science

102. Jahrestagung der DOG

Deutsche Ophthalmologische Gesellschaft e. V.

23. bis 26.09.2004, Berlin

Diagnosis of acquired colour vision disturbances in patients with arterial hypertension: sensitivity of HMC anomaloscope

Meeting Abstract

  • corresponding author A. Schröder - Department of Ophthalmology, Medical School of Hanover
  • M. Ahrens - Department of Ophthalmology, Medical School of Hanover
  • R. Gockeln - Department of Ophthalmology, Medical School of Hanover
  • M. Meyer - Department of Ophthalmology, Medical School of Hanover
  • C. Erb - Department of Ophthalmology, Medical School of Hanover

Evidenzbasierte Medizin - Anspruch und Wirklichkeit. 102. Jahrestagung der Deutschen Ophthalmologischen Gesellschaft. Berlin, 23.-26.09.2004. Düsseldorf, Köln: German Medical Science; 2004. Doc04dogP 154

Die elektronische Version dieses Artikels ist vollständig und ist verfügbar unter: http://www.egms.de/de/meetings/dog2004/04dog645.shtml

Veröffentlicht: 22. September 2004

© 2004 Schröder et al.
Dieser Artikel ist ein Open Access-Artikel und steht unter den Creative Commons Lizenzbedingungen (http://creativecommons.org/licenses/by-nc-nd/3.0/deed.de). Er darf vervielfältigt, verbreitet und öffentlich zugänglich gemacht werden, vorausgesetzt dass Autor und Quelle genannt werden.


Gliederung

Text

Objective

The aim of the present study was to proove the value of the HMC-anomaloscope with the standard 2°-ocular to detect acquired colour vision disturbances in patients with arterial hypertension.

Methods

Sixty-one patients (f:m=33:28) with arterial hypertension and without damages in end-organs were included in the study being divided into 3 groups according to their blood pressure levels during their long-term treatment: Group 1: systolic/diastolic blood pressure: 120-139/80-89mm Hg (n=17, f:m=12:5, average age = 55±14 years), group 2: systolic/diastolic blood pressure: 140-159/90-99mm Hg (n=25, f:m= 10:15, average age = 56±12 years), group 3: systolic/diastolic blood pressure: 160-179/100-109mm Hg (n=19, f:m= 11:8, average age = 55±11 years). They were compared to 20 healthy controls (f:m=12:8, average age = 54±12 years). Exlusion criteria were eye and general diseases. Beside the ophthalmological status (visual acuity, refraction, intraocular pressure, cup/disk ratio, fundus) the HMC-anomalscope was applied and the Moreland-and Raleigh match calculated. Statistical analysis was performed with the Mann-Whitney-U-Test and Wilcoxon-Test.

Results

The ophthalmological examinations showed a fundus hypertonicus stages I-II in 15 patients. Statistic analysis showed no significant difference of Moreland- and Raleigh match between the patients with arterial hypertension and the control group (Mann-Whitney-U-test: p>0.05). There was also no significant difference between the three hypertonic groups (Mann-Whitney-U-test: p>0.05).

Conclusions

The examination of acquired colour vision disturbances in patients with arterial hypertension using the HCM-anomaloscope seems to be less sensitive to the cap-sorting test Roth 28-hue (E) desaturated. Probably this results are caused by the small visual field of 2°. Further studies are necessary to clarify the value of increased visual field.