gms | German Medical Science

102. Jahrestagung der DOG

Deutsche Ophthalmologische Gesellschaft e. V.

23. bis 26.09.2004, Berlin

Miyake/Apple posterior view video analysis of capsular bag changes during sealed capsule irrigation (SCI)

Meeting Abstract

  • corresponding author A. J. Reuland - Heidelberg IOL & Refractive Surgery Research Group, Universitäts-Augenklinik, Heidelberg
  • I. J. Limberger - Heidelberg IOL & Refractive Surgery Research Group, Universitäts-Augenklinik, Heidelberg
  • M. S. Leuchtenberger - Heidelberg IOL & Refractive Surgery Research Group, Universitäts-Augenklinik, Heidelberg
  • T. M. Rabsilber - Heidelberg IOL & Refractive Surgery Research Group, Universitäts-Augenklinik, Heidelberg
  • M. P. Holzer - Heidelberg IOL & Refractive Surgery Research Group, Universitäts-Augenklinik, Heidelberg
  • G. U. Auffarth - Heidelberg IOL & Refractive Surgery Research Group, Universitäts-Augenklinik, Heidelberg

Evidenzbasierte Medizin - Anspruch und Wirklichkeit. 102. Jahrestagung der Deutschen Ophthalmologischen Gesellschaft. Berlin, 23.-26.09.2004. Düsseldorf, Köln: German Medical Science; 2004. Doc04dogDO.10.07

The electronic version of this article is the complete one and can be found online at: http://www.egms.de/en/meetings/dog2004/04dog091.shtml

Published: September 22, 2004

© 2004 Reuland et al.
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by-nc-nd/3.0/deed.en). You are free: to Share – to copy, distribute and transmit the work, provided the original author and source are credited.


Outline

Text

Objective

To study sealing capacity, capsular bag changes and zonular stress during sealed capsule irrigation.

Methods

In a laboratory study sealed capsule irrigation was performed in ten pig eyes after CCC and removal of the lens. After applying vacuum, fluoresceine dye was injected in the capsular bag. Capsular bag changes were studied using the Miyake/Apple posterior view.

Results

In all ten pig eyes sealed capsule irrigation resulted in no leakage during irrigation. No visible capsular bag damage occurred. Zonular stress during application of vacuum and during irrigation was minimal.

Conclusions

In a laboratory pig eye model, application of sealed capsule irrigation resulted in a tight vacuum, no capsular damage and minimal zonular stress.