gms | German Medical Science

GMS German Plastic, Reconstructive and Aesthetic Surgery – Burn and Hand Surgery

Deutsche Gesellschaft der Plastischen, Rekonstruktiven und Ästhetischen Chirurgen (DGPRÄC)
Deutsche Gesellschaft für Verbrennungsmedizin (DGV)

ISSN 2193-7052

Digital pressure ulcer after pulse oximetry

Digitales Druckulkus nach Pulsoxymetrie

Case Report

Search Medline for

  • corresponding author Philip H. Zeplin - Universitätsklinikum Leipzig, Department für Operative Medizin, Abteilung für Plastische, Ästhetische und spezielle Handchirurgie, Leipzig, Germany

GMS Ger Plast Reconstr Aesthet Surg 2013;3:Doc02

doi: 10.3205/gpras000012, urn:nbn:de:0183-gpras0000127

Published: June 5, 2013

© 2013 Zeplin.
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by-nc-nd/3.0/deed.en). You are free: to Share – to copy, distribute and transmit the work, provided the original author and source are credited.


Abstract

In emergency medical service, in intensive care unit and anaesthesia oxygenation is monitored with pulse oximetry apparatus. Pulse oximetry probe is usually attached to the finger, toe or earlobe. To the best of our knowledge this is the first case report describing the occurrence of a pressure ulcer after finger pulse oximetry measurement.

Keywords: pressure ulcer, finger pulse oximetry

Zusammenfassung

Sowohl in der Notfall- und Intensivmedizin als auch in der Anästhesie wird die Sauerstoffsättigung des Blutes mit Pulsoxymetern ermittelt. Diese Pulsoxymeter werden üblicherweise an den Fingern, den Zehen oder dem Ohrläppchen angebracht. Wir beschreiben einen Fall, bei dem es nach Anlage eines Fingerclip-Pulsoxymeters zur Ausbildung eines operationsbedürftigen Druckulkus kam.

Schlüsselwörter: Druckulkus, Fingerclip-Pulsoxymeter


Case report

A 76-year-old man with insulin dependent diabetes mellitus type II, renal insufficiency caused by diabetic nephropathy had an arteriovenous shunt for dialysis on the right arm. Because of an intercommisural mitral valve insufficiency he underwent mitral valve clipping. The mitraclip therapy procedure was done under general anaesthesia and takes approximately 3.5 hours. A pulse oximeter probe was placed on the right index finger to allow continuous monitoring throughout the procedure. After removal of the pulse oximeter clip an unspecific flush occurred in the radiodorsal middle phalanx area. Over the next four weeks a sharply demarcated skin lesion developed and continued to worsen into result shown in Figure 1 [Fig. 1]. The patient stated that he had never felt any pain. The physical and radiological examination revealed full-thickness skin damage extended into the subcutaneous tissue layer and the extensor tendon. The lesion was diagnosed as a grade IV pressure ulcer. After surgical debridement the remaining defect was covered by a reversed cross-finger flap.

Diabetes is strongly associated with both micro- and macrovascular complications that encourage the development of peripheral vascular disease and neuropathy. By impairing the blood flow and loss of sensation the risk for developing pressure ulcers – particularly in the feet – increases [1]. In emergency medical service, in intensive care unit and anaesthesia oxygenation is monitored with pulse oximetry apparatus. Pulse oximetry probe is usually attached to the finger, toe or earlobe. One case of grade II pressure ulcer on a patient’s ear as a result of pulse oximetry probe has been described [2]. To the best of our knowledge this is the first case report describing the occurrence of a pressure ulcer after finger pulse oximetry measurement. Pressure is assumed to be the most important single factor in the development of pressure ulcers. In healthy individuals capillary filling pressure of the finger arteries at heart level lies between 12–50 mmHg. Values of >30 mmHg can only be measured in warm and vasodilated state [3]. Using a pressure measuring instrument we calculated the pressure of a correct attached pulse oximeter finger clip with 18 mmHg. Through longer period of time incorrect attached pulse oximeter finger clips can induce pressure ulcer. This indicates a correct use of finger pulse oximeter especially in patients with assumed capillary pressure. This case shows that pressure ulcers not only develop on predilection sites and continuous checks of all instruments attached to the patient are suggested.


Notes

Competing interests

The author declares that he has no competing interests.


References

1.
Jeffcoate WJ, Harding KG. Diabetic foot ulcers. Lancet. 2003 May 3;361(9368):1545-51. DOI: 10.1016/S0140-6736(03)13169-8 External link
2.
Iranmanesh S, Rafiei H, Esmaeili Abdar M. A case of pressure ulcer development on a patient's ear as a result of pulse oximetry probe. Int Wound J. 2012 Dec;9(6):701-2. DOI: 10.1111/j.1742-481X.2011.00906.x External link
3.
Levick JR, Michel CC. Capillary pressures in the fingers and toes [proceedings]. J Physiol. 1976 Sep;260(2):57P.