gms | German Medical Science

33. Internationale Konferenz für Elektrokardiographie

Internationale Konferenz für Elektrokardiographie

HyperQ - a novel technique for detecting stress-induced ischemia using analysis of the ECG depolarization phase

Meeting Abstract

  • corresponding author presenting/speaker E. Toledo - BSP, Tel Aviv, Tel Aviv, Israel
  • O. Bregman-Amitai - BSP, Tel Aviv, Tel Aviv, Israel
  • A. Beker - BSP, Tel Aviv, Tel Aviv, Israel
  • M. Gadot - Cardiology Dep., Rabin Medical Center, Petah Tikva, Israel
  • B. Strasberg - Cardiology Dep., Rabin Medical Center, Petah Tikva, Israel
  • N. Zafrir - Cardiology Dep., Rabin Medical Center, Petah Tikva, Israel

33rd International Congress on Electrocardiology. Cologne, 28.06.-01.07.2006. Düsseldorf, Köln: German Medical Science; 2007. Doc06ice006

Die elektronische Version dieses Artikels ist vollständig und ist verfügbar unter: http://www.egms.de/de/meetings/ice2006/06ice006.shtml

Veröffentlicht: 8. Februar 2007

© 2007 Toledo et al.
Dieser Artikel ist ein Open Access-Artikel und steht unter den Creative Commons Lizenzbedingungen (http://creativecommons.org/licenses/by-nc-nd/3.0/deed.de). Er darf vervielfältigt, verbreitet und öffentlich zugänglich gemacht werden, vorausgesetzt dass Autor und Quelle genannt werden.


Gliederung

Text

Electrophysiogical detection of stress-induced myocardial ischemia is typically based on identifying changes in the repolarization phase, yet with limited accuracy. A new technology, which quantifies ischemic changes in the depolarization phase of the cardiac cycle (mid-QRS potentials) using analysis of high frequency components, was reported to better identify stress-induced ischemia. Question. Our aim was to test the performance of this technique in patients undergoing exercise myocardial perfusion SPECT (MPS). Methods. MPS was performed in 95 consecutive patients (age: 62±11 yo, 72 males) and used as the gold standard for ischemia. Conventional exercise ECG recording was combined with high resolution ECG acquisition, which was digitized and analyzed using the HyperQ™ System (BSP, Israel). The relative intensity change in high frequency mid-QRS components (HyperQ) during exercise was used as an index of ischemia. Results. Analysis was possible in 85 patients of whom 33 exhibited MPS ischemia. Ischemia was characterized by reduction in HyperQ intensity (see Figure 1 [Fig. 1]). The HyperQ index of ischemia was found more sensitive than the conventional ST analysis (76% vs 59%, p<0.01) and with better specificity (85% vs 57%, p<0.01). Conclusions. HyperQ analysis presents a significant improvement to current stress ECG in detecting ischemia and may thus aid in enhancing the non-invasive diagnosis of ischemic heart disease.