gms | German Medical Science

102. Jahrestagung der DOG

Deutsche Ophthalmologische Gesellschaft e. V.

23. bis 26.09.2004, Berlin

IOL power calculation following excimer-laser surgery

Meeting Abstract

  • corresponding author T.M. Rabsilber - Heidelberg Research Group Intraocular Lenses and Refractive Surgery, Department of Ophthalmology, University of Heidelberg, Heidelberg
  • A.J. Reuland - Heidelberg Research Group Intraocular Lenses and Refractive Surgery, Department of Ophthalmology, University of Heidelberg, Heidelberg
  • J. Schweipert - Heidelberg Research Group Intraocular Lenses and Refractive Surgery, Department of Ophthalmology, University of Heidelberg, Heidelberg
  • I.J. Limberger - Heidelberg Research Group Intraocular Lenses and Refractive Surgery, Department of Ophthalmology, University of Heidelberg, Heidelberg
  • M.P. Holzer - Heidelberg Research Group Intraocular Lenses and Refractive Surgery, Department of Ophthalmology, University of Heidelberg, Heidelberg
  • G.U. Auffarth - Heidelberg Research Group Intraocular Lenses and Refractive Surgery, Department of Ophthalmology, University of Heidelberg, Heidelberg

Evidenzbasierte Medizin - Anspruch und Wirklichkeit. 102. Jahrestagung der Deutschen Ophthalmologischen Gesellschaft. Berlin, 23.-26.09.2004. Düsseldorf, Köln: German Medical Science; 2004. Doc04dogP 071

Die elektronische Version dieses Artikels ist vollständig und ist verfügbar unter: http://www.egms.de/de/meetings/dog2004/04dog562.shtml

Veröffentlicht: 22. September 2004

© 2004 Rabsilber et al.
Dieser Artikel ist ein Open Access-Artikel und steht unter den Creative Commons Lizenzbedingungen (http://creativecommons.org/licenses/by-nc-nd/3.0/deed.de). Er darf vervielfältigt, verbreitet und öffentlich zugänglich gemacht werden, vorausgesetzt dass Autor und Quelle genannt werden.


Gliederung

Text

Objective

To evaluate the IOL power calculation software OKULIX in patients after excimer laser surgery with age related cataract formation.

Methods

12 eyes of 8 patients underwent excimer laser treatment between 1985 and 2000. Due to age related lens opacification, cataract surgery was performed and the IOL was calculated preoperatively using the OKULIX software. Keratometry data measured with the C-Scan (Technomed) was imported. Axial length evaluated with the IOLMaster was entered manually. Postoperatively, the accuracy of IOL calculation was investigated by comparing attempted versus achieved spherical equivalent.

Results

Mean patient age was 54.3±9.1 years. An AR40e hydrophobic acrylic IOL with a lens power between 12 and 22 D was implanted in all cases. Mean spherical equivalent was -3.5±2.8 D preoperatively and -0.76±1.1 D postoperatively.

Conclusions

The OKULIX software ist suitable and reliable to calculate IOL power after excimer laser surgery.