gms | German Medical Science

27. Internationaler Kongress der Deutschen Ophthalmochirurgen

15. bis 17.05.2014, Nürnberg

Estimation of femtosecond lenticule extraction after automated anterior lamellar keratoplasty (K)

Meeting Abstract

  • Alexander Ovchinnikov - IRTC Eye Microsurgery Ekaterinburg Center, Laser Surgery Department, Ekaterinburg, Russia
  • Sergey Rebrikov - IRTC Eye Microsurgery Ekaterinburg Center, Laser Surgery Department, Ekaterinburg, Russia
  • Oleg Kostin - IRTC Eye Microsurgery Ekaterinburg Center, Laser Surgery Department, Ekaterinburg, Russia
  • Alexey Stepanov - IRTC Eye Microsurgery Ekaterinburg Center, Laser Surgery Department, Ekaterinburg, Russia

27. Internationaler Kongress der Deutschen Ophthalmochirurgen. Nürnberg, 15.-17.05.2014. Düsseldorf: German Medical Science GMS Publishing House; 2014. DocWK 4.1

doi: 10.3205/14doc116, urn:nbn:de:0183-14doc1166

Veröffentlicht: 5. Mai 2014

© 2014 Ovchinnikov et al.
Dieser Artikel ist ein Open Access-Artikel und steht unter den Creative Commons Lizenzbedingungen (http://creativecommons.org/licenses/by-nc-nd/3.0/deed.de). Er darf vervielfältigt, verbreitet und öffentlich zugänglich gemacht werden, vorausgesetzt dass Autor und Quelle genannt werden.


Gliederung

Text

Purpose: Estimation of the results of FLEx operation using VisuMax femtosecond laser (Carl Zeiss Meditec) after automated anterior lamellar keratoplasty in the eyes with myopia and myopic astigmatism.

Methods: The study group included 7 patients (7 eyes). In 3 cases automated anterior lamellar keratoplasty was performed for corneal opacities after keratitis, in 4 cases – for keratoconus. FLEx operation was performed in terms from 1 year to 2 years 8 months (mean, 20 months) after anterior lamellar keratoplasty and from 3 months to 1 year 11 months after corneal sutures removal (mean, 16 months).

Results: Uncorrected visual acuity before surgery was 0.06 ± 0.07, after surgery it made 0.34 ± 0.16 (p>0.05). Spherical equivalent (SE) before surgery was –5.88 ± 3.19D, after surgery it made –0.34 ± 1.32 D (p>0.05). Corrected visual acuity before surgery was 0.51 ± 0.1 and after surgery it made 0.54 ± 0.11 (p>0.05).

Conclusions: The results achieved in our patients show that FLEx operation may be a method of choice for correction of myopia and myopic astigmatism after automated anterior lamellar keratoplasty. Further dynamic follow-up of these patients is required.