gms | German Medical Science

67. Jahrestagung der Deutschen Gesellschaft für Unfallchirurgie
89. Tagung der Deutschen Gesellschaft für Orthopädie und Orthopädische Chirurgie
44. Tagung des Berufsverbandes der Fachärzte für Orthopädie

11. bis 16.11.2003, Messe/ICC Berlin

Estimation of the anaesthetics on the somatosensory potentials recorded during the scoliosis correction with CD and CD Hopf methods

Meeting Abstract (DGOOC 2003)

Suche in Medline nach

  • corresponding author Maciej Glowacki - University of Medical Science, Poznan, Poland, 28 czerwca 1956 No 135/147, 61-545, Poznan, Phone: 0048 (61) 83-10-375, Fax: 0048 (61) 83-10-173
  • J. Huber - University of Medical Science, Poznan, Poland, 28 czerwca 1956 No 135/147, 61-545, Poznan, Phone: 0048 (61) 83-10-375, Fax: 0048 (61) 83-10-173
  • A. Szulc - University of Medical Science, Poznan, Poland, 28 czerwca 1956 No 135/147, 61-545, Poznan, Phone: 0048 (61) 83-10-375, Fax: 0048 (61) 83-10-173
  • A. Wilusz - University of Medical Science, Poznan, Poland, 28 czerwca 1956 No 135/147, 61-545, Poznan, Phone: 0048 (61) 83-10-375, Fax: 0048 (61) 83-10-173

Deutsche Gesellschaft für Unfallchirurgie. Deutsche Gesellschaft für Orthopädie und orthopädische Chirurgie. Berufsverband der Fachärzte für Orthopädie. 67. Jahrestagung der Deutschen Gesellschaft für Unfallchirurgie, 89. Tagung der Deutschen Gesellschaft für Orthopädie und Orthopädische Chirurgie und 44. Tagung des Berufsverbandes der Fachärzte für Orthopädie. Berlin, 11.-16.11.2003. Düsseldorf, Köln: German Medical Science; 2003. Doc03dguX-98

Die elektronische Version dieses Artikels ist vollständig und ist verfügbar unter: http://www.egms.de/de/meetings/dgu2003/03dgu1110.shtml

Veröffentlicht: 11. November 2003

© 2003 Glowacki et al.
Dieser Artikel ist ein Open Access-Artikel und steht unter den Creative Commons Lizenzbedingungen (http://creativecommons.org/licenses/by-nc-nd/3.0/deed.de). Er darf vervielfältigt, verbreitet und öffentlich zugänglich gemacht werden, vorausgesetzt dass Autor und Quelle genannt werden.


Gliederung

Text

The aim of study was estimation of the anaesthetics influence on the morphology of somatosensory potentials (SEPs) recorded oververtebrally at the cervical level when correction of scoliosis with CD and CD Hopf methods were performed.

Material and methods

Amplitudes and latencies of the averaged SEPs recorded during the correction of scoliosis in 16 subjects with CD and in 11 subjects treated with CD-Hopf were analyzed. Subjects were inhalatory anaesthetized with O2 and N2O mixture with the intravenal administration of Scoline, Pavulon, Fenthanyl and barbiturates in different combinations.

Results

In SEPs recorded before CD instrumentation was applied, mean of latencies was 19.7ms and in CD Hopf 19.0 ms. During the distraction, SEPs latencies were prolonged up to 20.6ms and 19.5ms respectively. These changes were accompanied by decreasing amplitudes at 30 percent in CD group and at 10 percent in CD Hopf group of patients. Mean values of SEPs latencies recorded after the surgery was completed in both groups of patients were 19.6ms in case of CD method and 18.6ms in case of CD-Hopf method. In all cases amplitudes of potentials reached the values almost the same or higher (especially with CD Hopf surgery) comparing to those which were recorded in first stages of surgeries when different combinations of anaesthetics were applied.

Conclusions

1. This comparison shows less extend of changes in parameters of amplitudes and latencies of SEPs recorded intraoperatively in cases of CDHopf than CD instrumentations. 2. Parameters of SEPs recorded oververtebrally at cervical level are not worse when different anaesthetics are applied during the general anaesthesia.