gms | German Medical Science

27. Kongress der Deutschsprachigen Gesellschaft für Intraokularlinsen-Implantation, Interventionelle und Refraktive Chirurgie (DGII)

Gesellschaft für Intraokularlinsen-Implantation, Interventionelle und Refraktive Chirurgie (DGII)

11.04. - 13.04.2013, Heidelberg

One year follow-up results of presbyopia Lasik correction, Supracor, in Korean

Meeting Abstract

Suche in Medline nach

  • Hung-Won Tchah - Seoul/ROK

Deutschsprachige Gesellschaft für Intraokularlinsen-Implantation, Interventionelle und Refraktive Chirurgie. 27. Kongress der Deutschsprachigen Gesellschaft für Intraokularlinsen-Implantation, Interventionelle und Refraktive Chirurgie (DGII). Heidelberg, 11.-13.04.2013. Düsseldorf: German Medical Science GMS Publishing House; 2013. Doc13dgii012

doi: 10.3205/13dgii012, urn:nbn:de:0183-13dgii0126

Veröffentlicht: 5. April 2013

© 2013 Tchah.
Dieser Artikel ist ein Open Access-Artikel und steht unter den Creative Commons Lizenzbedingungen (http://creativecommons.org/licenses/by-nc-nd/3.0/deed.de). Er darf vervielfältigt, verbreitet und öffentlich zugänglich gemacht werden, vorausgesetzt dass Autor und Quelle genannt werden.


Gliederung

Text

Purpose: To evaluate the safety and efficacy of new presbyopia laser correction procesure, Supracor, in Korean patients.

Patients and methods: Inclusion criteria were; age over 50 years old, near add greater than +1.75 D, refractive error greater than +1.0 D, and no history of eye surgery. Supracor procedure with Technolas 217p excimer laser (B&L) was performed to treat hyperopia and presbyopia. This new algorithm was supposed to induce central corneal elevation resulting in negative spherical aberration. Post-operative VA and visual symptoms were evaluated up to 12 months.

Results: Fourteen patients (28 eyes) were in this study. Average age was 57.3+/- 4.2. BCDVA better than 0.8 was achieved in all patients at post-operative 6 and 12 months. Negative spherical aberration increased postoperatively in all eyes. Binocular UCNA better than 0.4, which needed for news paper reading, was achieved 75.4% at post-operative 3 months, 45.5% at 6 months and 66.7% at 12 months. Overall satisfaction rate was about 70% at post-operative 12months, however, 83% of patients was willing to recommend this procedure to others. Compared with European study, satisfaction rate was lower.

Conclusion: Supracor treatment induced negative spherical aberration, increased NVA. and seemed to be safe. However, prebyopia correcting effect seemed to decrease over the time. Ethnical or cultural factors might be the reasons for different results from European study.