gms | German Medical Science

GMS Ophthalmology Cases – An Open Access Journal

Bundesverband Deutscher OphthalmoChirurgen e. V. (BDOC)

ISSN 2193-1496

Perfluoro-n-octane mimicking an intraocular foreign body

Case Report

Search Medline for

  • Prabu Baskaran - Department of Vitreo-Retina, Aravind Eye Hospital and Postgraduate Institute of Ophthalmology, Pondicherry, India
  • corresponding author Pratyusha Ganne - Department of Vitreo-Retina, Aravind Eye Hospital and Postgraduate Institute of Ophthalmology, Pondicherry, India
  • Nagesha C Krishnappa - Department of Vitreo-Retina, Aravind Eye Hospital and Postgraduate Institute of Ophthalmology, Pondicherry, India

GMS Ophthalmol Cases 2017;7:Doc30

doi: 10.3205/oc000081, urn:nbn:de:0183-oc0000819

Published: December 15, 2017

© 2017 Baskaran et al.
This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 License. See license information at http://creativecommons.org/licenses/by/4.0/.


Abstract

Retained intraocular foreign body (IOFB) is a major cause of visual loss following open globe injuries. Detecting the presence and accurate localization of IOFB in the setting of an open globe injury remains a challenge. There can be various mimics of intraocular IOFB on imaging including air, ocular calcifications, etc. Here, we describe a case of open globe injury wherein a retained perfluoro-n-octane bubble mimicked a retained intraocular foreign body.

Keywords: perfluoro-n-octane, intraocular foreign body, rodio-dense, CT scan


Introduction

Retained intraocular foreign body (IOFB) is a major cause of visual loss following open globe injuries. Studies have shown that up to 40 percent of open globe injuries can have retained IOFB [1]. Loss of vision can result from endophthalmitis, retinal detachment or metallosis. Hence, IOFB mandates emergency removal. Detecting the presence and accurate localization of IOFB in the setting of an open globe injury remains a challenge. The various modalities used include computed tomography scan (CT), magnetic resonance imaging, ultrasonography, and plain film x-ray. The sensitivity and specificity for detection depends on the imaging modality and the type of IOFB [2]. There can be various mimics of intraocular IOFB on imaging including air, ocular calcifications, etc.


Purpose

To report a case of open globe injury wherein a retained perfluoro-n-octane bubble mimicked an intraocular foreign body necessitating a second surgery.


Case description

A 10-year-old boy presented to the emergency with a history of blast injury. His visual acuity at presentation was 6/6 in the right eye and hand movements in the left. Ocular examination showed a full thickness corneal laceration measuring 10 mm passing through the center of the left cornea. He underwent corneal tear suturing with lens extraction as an emergency procedure by the cornea team (Figure 1 [Fig. 1]). Intraoperatively, there was a posterior capsular rent with cortex drop which necessitated a pars plana vitrectomy. During pars plana vitrectomy, three non-metallic foreign bodies ranging in size from 0.5 to 2 mm were removed from the posterior segment. Perfluoro-n-octane was used to assist the surgical removal. The visibility throughout the surgery was poor due to the corneal wound. On the first postoperative day, the posterior segment could not be examined clinically due to corneal edema and astigmatism. Ultrasonography of the posterior segment revealed a high reflective echo with back shadowing in the posterior vitreous (Figure 2 [Fig. 2]). A plain computed tomography scan (CT) was done which revealed a round, 1.9 mm x 2.1 mm sized radio dense (400 Hounsfield units) lesion close to the retina in the left globe (Figure 3A [Fig. 3]). With the suspicion of a retained intraocular foreign body, the patient was taken up for a repeated pars plana vitrectomy. Intraoperatively, there was no evidence of a foreign body. Instead, there was a small bubble of perfluoro-n-octane over the posterior pole. The bubble was aspirated. CT scan was repeated in the postoperative period which showed the absence of any radio dense lesion (Figure 3B [Fig. 3]).


Discussion

Penetrating injuries with a retained intraocular foreign body are an important cause of blindness among children. Studies have shown that the removal of intraocular foreign bodies within 24 hours from the time of trauma significantly reduces the risk of endophthalmitis [3]. CT scan is the modality of imaging for the detection of IOFB. Different foreign bodies produce different degrees of attenuation on a CT scan. Metallic foreign bodies cause the highest degree of attenuation while wood causes the lowest [2]. Perfluoro-n-octane has been used to aid complicated vitreoretinal surgeries. It is a high density, synthetic fluorinated compound. Although it is completely removed at the end of surgery, small amounts may be retained especially when the visibility during the surgery is poor. Owing to their high density, they show up as hyperintense lesions on ultrasonography and radio dense lesions on a CT scan [4]. In the present case, the visibility during the first vitrectomy was poor and multiple foreign bodies were removed during this time. Hence, there was a high index of suspicion of a missed foreign body. This subjected the child to an unnecessary second surgery with attendant risks of general anesthesia. Liu et al. [5] have published a similar case report of retained perfluorodecalin masquerading as a retained intraocular foreign body. The authors differentiated the bubble from an IOFB by its ability to move freely, its smooth contour and the lack of any metallic streak artifact.

This case emphasizes the need to exercise caution when making a diagnosis of an IOFB especially when the contours of the foreign body are smooth and regular.


Notes

Competing interests

The authors declare that they have no competing interests.


References

1.
Greven CM, Engelbrecht NE, Slusher MM, Nagy SS. Intraocular foreign bodies: management, prognostic factors, and visual outcomes. Ophthalmology. 2000 Mar;107(3):608-12. DOI: 10.1016/S0161-6420(99)00134-7 External link
2.
Modjtahedi BS, Rong A, Bobinski M, McGahan J, Morse LS. Imaging characteristics of intraocular foreign bodies: a comparative study of plain film X-ray, computed tomography, ultrasound, and magnetic resonance imaging. Retina (Philadelphia, Pa). 2015 Jan;35(1):95-104. DOI: 10.1097/IAE.0000000000000271 External link
3.
Jonas JB, Knorr HL, Budde WM. Prognostic factors in ocular injuries caused by intraocular or retrobulbar foreign bodies. Ophthalmology. 2000 May;107(5):823-8. DOI: 10.1016/S0161-6420(00)00079-8 External link
4.
Christoforidis JB, Caruso PA, Curtin HD, Fiore T, D'Amico DJ. CT characteristics of intraocular perfluoro-N-octane. AJNR Am J Neuroradiol. 2003 Oct;24(9):1769-71.
5.
Liu DT, Fan AH, Lee VY, Lam DS. Residual intraocular perfluorodecalin masquerading as a retained intraocular foreign body: how to differentiate by simple measures. Acta Ophthalmol. 2010 Mar;88(2):e46-7. DOI: 10.1111/j.1755-3768.2008.01361.x External link